Installation conductor
H05V-U, H07V-U
Copper conductor
PVC insulation
Application:
For fixed installation in lighting networks, power and signal systems, wiring in control boards, machines and instruments.
Technical characteristics:
- Produced according to DIN VDE 0281, part 3
- Rated voltage:
- For H05V-U from 0.50 mm2 to 1.00 mm2: U0/U – 300/500 V
- For H07V-U from 1.50 mm2 to 10 mm2: U0/U – 450/750 V
- Test Voltage:
- For H05V-U from 0.50 mm2 to 1.00 mm2: 2000 V
- For H07V-U from 1.50 mm2 to 10 mm2: 2500 V
- Maximum conductor temperature: +70 0C
- Maximum conductor temperature at short circuit for 5 seconds: +160 0C
- Temperature Range: from -30 0C to +50 0C
- Minimum temperature during installation: -5 0C
- Minimum bending radius during installation:
- For diameters up to 10 mm - 10 D
- For diameters above 10 mm - 15 D
- Flame test: flame retardant according to IEC 60332-1
Cable Design:
- Copper conductors
- Flexibility class 1 according to DIN VDE 0295 (HD 383)
- Insulation: PVC
Colour coding:
- White, Gray, Black, Blue, Brown, Red, Yellow-green
Data:
Nominal Section, mm2 |
Nominal Cable Diameter, mm |
Nominal Copper Weight, kg/km |
Nominal Cable Weight, kg/km |
0.5 |
2.1 |
4.8 |
9.1 |
0.75 |
2.2 |
7.2 |
12.0 |
1 |
2.4 |
9.6 |
15.0 |
1.5 |
2.9 |
14.4 |
22.0 |
2.5 |
3.5 |
24.0 |
34.0 |
4 |
3.9 |
38.4 |
50.0 |
6 |
4.5 |
57.6 |
70.0 |
10 |
5.7 |
96.0 |
117.0 |